ATHEN Highlights
Energy efficiency & total cost of ownership
ATHEN is a double world champion with the lowest power consumption and lowest total cost of ownership (TCO) on the global market.
Largest capacity
ATHEN provides the largest capacity of all AHT refrigerators and freezers for your products. With up to 1071 litres, three pizzas fit one behind the other, for example, in the ATHEN 250.
Environment and climate
ATHEN units are completely CFC and HFC free and use the ecologically harmless and natural refrigerant propane (R290). R290 has the lowest GWP on the market. This makes them particularly environmentally friendly.
Compatible with AMS
Our Active Monitoring System (AMS) allows us to detect problems before you notice them. As an essential add-on to all AHT products, the AMS makes it much easier for you to manage and monitor the AHT cooling systems in your stores.
ATHENS XL 175 (-) JKRT
ATHEN XL
175 (-) JKRT
Type of refrigerating appliance with a direct sales function |
Supermarket cabinet |
Use |
Display & Sale |
Temperature class acc. EN 23953-2 |
L1 |
Climate class acc. EN 23953-2 |
3 |
Cabinet family code acc. EN 23953-2 |
HF6 |
Energy efficiency index EEI |
39 % |
Energy efficiency class |
D |
- Dimensions
- gross content 1011 Liter
net content min.** 706 Liter
total display area min.** (TDA) 1,25 m²
length outside / inside 1752 / 1623 mm
depth outside / inside 994 / 863 mm
height outside front / rear 803 / 910 mm
stacking height** front / rear 600 / 600 mm
net weight** 145 kg
gross weight** 152 kg
- Operation
- ambient temperature (min … max) 16 … 25 °C
ambient humidity (RH) max. 60 %
recommended temperature(s) for optimised food storage -18 °C
sound pressure in 1 m distance 44 dB(A)
blowing agent R-601 (HC) GWP 5
- Electrical supply
- nominal voltage / frequency 220-240 / 50 V / Hz
nominal power max. acc. EN 60335-2-89 400 W
nominal power during defrost max. 1300 W
nominal current during defrost max. 6,0 A
fuse protection RCBO, 30mA, C16
defrost heater power max. 600 W
length of power supply cord 2400 mm
- Light source parameters
- type of light source LED
energy efficiency class light source G
nominal power light max. 34 W
- Energy consumption
- daily energy consumption* Edaily 7,24 kWh/24h
annual energy consumption AE 2643,93 kWh/a
- HVAC
- rejected heat capacity* 302 W
dehumidification* 0 Liter/24h
- Refrigeration system
- refrigerant type R-290 (HC) GWP 3
refrigerant charge max. 0,130 kg
max. allowable operating pressure 30 bar
- General
- minimum duration of the guarantee offered by the supplier
*… declared for climate class 3, test procedure according to EN 23953-2
**… with process-related interior fitting
“The manufacturer reserves the right to change the product specifications without notice”
ATHENS XL EC 207 (-) JKRT
ATHEN XL EC
207 (-) JKRT
Type of refrigerating appliance with a direct sales function |
Supermarket cabinet |
Use |
Display & Sale |
Temperature class acc. EN 23953-2 |
L1 |
Climate class acc. EN 23953-2 |
3 |
Cabinet family code acc. EN 23953-2 |
HF6 |
Energy efficiency index EEI |
38,2 % |
Energy efficiency class |
D |
- Dimensions
- gross content 1189Liter
net content min.** 864 Liter
total display area min.** (TDA) 1,43 m²
length outside / inside 2080 / 1948 mm
depth outside / inside 994 / 863 mm
height outside front / rear 800 / 910 mm
stacking height** front / rear 600 / 600 mm
net weight** 150 kg
gross weight** 161 kg
- Operation
- ambient temperature (min … max) 16 … 25 °C
ambient humidity (RH) max. 60 %
recommended temperature(s) for optimised food storage -18 °C
sound pressure in 1 m distance 44 dB(A)
blowing agent R-601 (HC) GWP 5
- Electrical supply
- nominal voltage / frequency 220-240 / 50 V / Hz
nominal power max. acc. EN 60335-2-89 470 W
nominal power during defrost max. 1300 W
nominal current during defrost max. 6,0 A
fuse protection RCBO, 30mA, C16
defrost heater power max. 600 W
length of power supply cord 2400 mm
- Light source parameters
- type of light source LED
energy efficiency class light source G
nominal power light max. 31 W
- Energy consumption
- daily energy consumption* Edaily 7,86 kWh/24h
annual energy consumption AE 2868,84 kWh/a
- HVAC
- rejected heat capacity* 327 W
dehumidification* 0 Liter/24h
- Refrigeration system
- refrigerant type R-290 (HC) GWP 3
refrigerant charge max. 0,140 kg
max. allowable operating pressure 30 bar
- General
- minimum duration of the guarantee offered by the supplier
*… declared for climate class 3, test procedure according to EN 23953-2
**… with process-related interior fitting
“The manufacturer reserves the right to change the product specifications without notice”
ATHENS XL 210 (-) JKRT
ATHEN XL
210 (-) JKRT
Type of refrigerating appliance with a direct sales function |
Supermarket cabinet |
Use |
Display & Sale |
Temperature class acc. EN 23953-2 |
L1 |
Climate class acc. EN 23953-2 |
3 |
Cabinet family code acc. EN 23953-2 |
HF6 |
Energy efficiency index EEI |
36,4 % |
Energy efficiency class |
D |
- Dimensions
- gross content 1244Liter
net content min.** 876 Liter
total display area min.** (TDA) 1,53 m²
length outside / inside 2102 / 1973 mm
depth outside / inside 994 / 863 mm
height outside front / rear 803 / 910 mm
stacking height** front / rear 600 / 600 mm
net weight** 176 kg
gross weight** 185 kg
- Operation
- ambient temperature (min … max) 16 … 25 °C
ambient humidity (RH) max. 60 %
recommended temperature(s) for optimised food storage -18 °C
sound pressure in 1 m distance 44 dB(A)
blowing agent R-601 (HC) GWP 5
- Electrical supply
- nominal voltage / frequency 220-240 / 50 V / Hz
nominal power max. acc. EN 60335-2-89 450 W
nominal power during defrost max. 1300 W
nominal current during defrost max. 6,0 A
fuse protection RCBO, 30mA, C16
defrost heater power max. 600 W
length of power supply cord 2400 mm
- Light source parameters
- type of light source LED
energy efficiency class light source G
nominal power light max. 39 W
- Energy consumption
- daily energy consumption* Edaily 7,91 kWh/24h
annual energy consumption AE 2885,92 kWh/a
- HVAC
- rejected heat capacity* 329 W
dehumidification* 0 Liter/24h
- Refrigeration system
- refrigerant type R-290 (HC) GWP 3
refrigerant charge max. 0,140 kg
max. allowable operating pressure 30 bar
- General
- minimum duration of the guarantee offered by the supplier
*… declared for climate class 3, test procedure according to EN 23953-2
**… with process-related interior fitting
“The manufacturer reserves the right to change the product specifications without notice”
ATHENS XL 250 (-) JKRT
ATHEN XL
250 (-) JKRT
Type of refrigerating appliance with a direct sales function |
Supermarket cabinet |
Use |
Display & Sale |
Temperature class acc. EN 23953-2 |
L1 |
Climate class acc. EN 23953-2 |
3 |
Cabinet family code acc. EN 23953-2 |
HF6 |
Energy efficiency index EEI |
34 % |
Energy efficiency class |
C |
- Dimensions
- gross content 1509 Liter
net content min.** 1071 Liter
total display area min.** (TDA) 1,86 m²
length outside / inside 2502 / 2373 mm
depth outside / inside 994 / 863 mm
height outside front / rear 803 / 910 mm
stacking height** front / rear 600 / 600 mm
net weight** 197 kg
gross weight** 208 kg
- Operation
- ambient temperature (min … max) 16 … 25 °C
ambient humidity (RH) max. 60 %
recommended temperature(s) for optimised food storage -18 °C
sound pressure in 1 m distance 44 dB(A)
blowing agent R-601 (HC) GWP 5
- Electrical supply
- nominal voltage / frequency 220-240 / 50 V / Hz
nominal power max. acc. EN 60335-2-89 450 W
nominal power during defrost max. 1300 W
nominal current during defrost max. 6,0 A
fuse protection RCBO, 30mA, C16
defrost heater power max. 600 W
length of power supply cord 2400 mm
- Light source parameters
- type of light source LED
energy efficiency class light source G
nominal power light max. 46 W
- Energy consumption
- daily energy consumption* Edaily 8,67 kWh/24h
annual energy consumption AE 3163,51 kWh/a
- HVAC
- rejected heat capacity* 361 W
dehumidification* 0 Liter/24h
- Refrigeration system
- refrigerant type R-290 (HC) GWP 3
refrigerant charge max. 0,150 kg
max. allowable operating pressure 30 bar
- General
- minimum duration of the guarantee offered by the supplier
*… declared for climate class 3, test procedure according to EN 23953-2
**… with process-related interior fitting
“The manufacturer reserves the right to change the product specifications without notice”
Only logged in customers who have purchased this product may leave a review.
Reviews
There are no reviews yet.