Naturally at your side

Paris

Table Energy Efficiency Class

Label EEI from/to
A 0 9.9
B 10 19.9
C 20 34.9
D 35 49.9
E 50 64.9
F 65 79.9
G 80 109.9
H 110

£2,419.61£3,016.32

SKU: N/A
Your price includes delivery to a UK Mainland, ground floor/clear access delivery point. Our drivers will deliver to the external entrance of your premises only. If you require your goods unpacked and positioned in store, please contact our sales office to discuss further.

Additional information

Models

Paris 145 JKRT, Paris 185 JKRT, Paris 210 JKRT, Paris 250 JKRT

Do you have access to a fork-lift on site

No, Yes

PARIS 145 JKRT

PARIS
145 JKRT

rating

Type of refrigerating appliance with a direct sales function Supermarket cabinet
Use Display & Sale
Temperature class acc. EN 23953-2 L1
Climate class acc. EN 23953-2 3
Cabinet family code acc. EN 23953-2 HF6
Energy efficiency index EEI 39,6 %
Energy efficiency class D
  • Dimensions
  • gross content 611 Liter
    net content min.** 422 Liter
    total display area min.** (TDA) 0,83
    length outside / inside 1457 / 1328 mm
    depth outside / inside 853 / 723 mm
    height outside front / rear 770 / 833 mm
    stacking height** front / rear 550 / 550 mm
    net weight** 89 kg
    gross weight** 96 kg
  • Operation
  • ambient temperature (min … max) 16 … 25 °C
    ambient humidity (RH) max. 60 %
    recommended temperature(s) for optimised food storage -18 °C
    sound pressure in 1 m distance 44 dB(A)
    blowing agent R-601 (HC) GWP 5
  • Electrical supply
  • nominal voltage / frequency 220-240 / 50 V / Hz
    nominal power max. acc. EN 60335-2-89 460 W
    nominal power during defrost max. 900 W
    nominal current during defrost max. 3,9 A
    fuse protection RCBO, 30mA, C16
    defrost heater power max. 0 W
    length of power supply cord 2400 mm
  • Light source parameters
  • type of light source LED
    energy efficiency class light source G
    nominal power light max. 28 W
  • Energy consumption
  • daily energy consumption* Edaily 5,46 kWh/24h
    annual energy consumption AE 1992,74 kWh/a
  • HVAC
  • rejected heat capacity* 227 W
    dehumidification* 0 Liter/24h
  • Refrigeration system
  • refrigerant type R-290 (HC) GWP 3
    refrigerant charge max. 0,100 kg
    max. allowable operating pressure 30 bar
  • General
  • minimum duration of the guarantee offered by the supplier

*… declared for climate class 3, test procedure according to EN 23953-2
**… with process-related interior fitting
“The manufacturer reserves the right to change the product specifications without notice”

PARIS 185 (-) JKRT

PARIS
185 (-) JKRT

rating

Type of refrigerating appliance with a direct sales function Supermarket cabinet
Use Display & Sale
Temperature class acc. EN 23953-2 L1
Climate class acc. EN 23953-2 3
Cabinet family code acc. EN 23953-2 HF6
Energy efficiency index EEI 36,6 %
Energy efficiency class D
  • Dimensions
  • gross content 760 Liter
    net content min.** 531 Liter
    total display area min.** (TDA) 1,03
    length outside / inside 1752 / 1623 mm
    depth outside / inside 853 / 723 mm
    height outside front / rear 770 / 833 mm
    stacking height** front / rear 550 / 550 mm
    net weight** 111 kg
    gross weight** 118 kg
  • Operation
  • ambient temperature (min … max) 16 … 25 °C
    ambient humidity (RH) max. 60 %
    recommended temperature(s) for optimised food storage -18 °C
    sound pressure in 1 m distance 44 dB(A)
    blowing agent R-601 (HC) GWP 5
  • Electrical supply
  • nominal voltage / frequency 220-240 / 50 V / Hz
    nominal power max. acc. EN 60335-2-89 460 W
    nominal power during defrost max. 900 W
    nominal current during defrost max. 3,9 A
    fuse protection RCBO, 30mA, C16
    defrost heater power max. 0 W
    length of power supply cord 2400 mm
  • Light source parameters
  • type of light source LED
    energy efficiency class light source G
    nominal power light max. 34 W
  • Energy consumption
  • daily energy consumption* Edaily 5,88 kWh/24h
    annual energy consumption AE 2147,90 kWh/a
  • HVAC
  • rejected heat capacity* 245 W
    dehumidification* 0 Liter/24h
  • Refrigeration system
  • refrigerant type R-290 (HC) GWP 3
    refrigerant charge max. 0,110 kg
    max. allowable operating pressure 30 bar
  • General
  • minimum duration of the guarantee offered by the supplier

*… declared for climate class 3, test procedure according to EN 23953-2
**… with process-related interior fitting
“The manufacturer reserves the right to change the product specifications without notice”

PARIS 210 (-) JKRT

PARIS
210 (-) JKRT

rating

Type of refrigerating appliance with a direct sales function Supermarket cabinet
Use Display & Sale
Temperature class acc. EN 23953-2 L1
Climate class acc. EN 23953-2 3
Cabinet family code acc. EN 23953-2 HF6
Energy efficiency index EEI 34 %
Energy efficiency class C
  • Dimensions
  • gross content 936 Liter
    net content min.** 660 Liter
    total display area min.** (TDA) 1,27
    length outside / inside 2102 / 1973 mm
    depth outside / inside 853 / 723 mm
    height outside front / rear 770 / 833 mm
    stacking height** front / rear 550 / 550 mm
    net weight** 145 kg
    gross weight** 154 kg
  • Operation
  • ambient temperature (min … max) 16 … 25 °C
    ambient humidity (RH) max. 60 %
    recommended temperature(s) for optimised food storage -18 °C
    sound pressure in 1 m distance 44 dB(A)
    blowing agent R-601 (HC) GWP 5
  • Electrical supply
  • nominal voltage / frequency 220-240 / 50 V / Hz
    nominal power max. acc. EN 60335-2-89 460 W
    nominal power during defrost max. 1300 W
    nominal current during defrost max. 6,0 A
    fuse protection RCBO, 30mA, C16
    defrost heater power max. 600 W
    length of power supply cord 2400 mm
  • Light source parameters
  • type of light source LED
    energy efficiency class light source G
    nominal power light max. 39 W
  • Energy consumption
  • daily energy consumption* Edaily 6,39 kWh/24h
    annual energy consumption AE 2331,53 kWh/a
  • HVAC
  • rejected heat capacity* 266 W
    dehumidification* 0 Liter/24h
  • Refrigeration system
  • refrigerant type R-290 (HC) GWP 3
    refrigerant charge max. 0,120 kg
    max. allowable operating pressure 30 bar
  • General
  • minimum duration of the guarantee offered by the supplier

*… declared for climate class 3, test procedure according to EN 23953-2
**… with process-related interior fitting
“The manufacturer reserves the right to change the product specifications without notice”

PARIS 250 (-) JKRT

PARIS
250 (-) JKRT

rating

Type of refrigerating appliance with a direct sales function Supermarket cabinet
Use Display & Sale
Temperature class acc. EN 23953-2 L1
Climate class acc. EN 23953-2 3
Cabinet family code acc. EN 23953-2 HF6
Energy efficiency index EEI 31,9 %
Energy efficiency class C
  • Dimensions
  • gross content 1136 Liter
    net content min.** 808 Liter
    total display area min.** (TDA) 1,54
    length outside / inside 2502 / 2373 mm
    depth outside / inside 853 / 723 mm
    height outside front / rear 770 / 833 mm
    stacking height** front / rear 550 / 550 mm
    net weight** 154 kg
    gross weight** 161 kg
  • Operation
  • ambient temperature (min … max) 16 … 25 °C
    ambient humidity (RH) max. 60 %
    recommended temperature(s) for optimised food storage -18 °C
    sound pressure in 1 m distance 44 dB(A)
    blowing agent R-601 (HC) GWP 5
  • Electrical supply
  • nominal voltage / frequency 220-240 / 50 V / Hz
    nominal power max. acc. EN 60335-2-89 460 W
    nominal power during defrost max. 1300 W
    nominal current during defrost max. 6,0 A
    fuse protection RCBO, 30mA, C16
    defrost heater power max. 600 W
    length of power supply cord 2400 mm
  • Light source parameters
  • type of light source LED
    energy efficiency class light source G
    nominal power light max. 46 W
  • Energy consumption
  • daily energy consumption* Edaily 6,96 kWh/24h
    annual energy consumption AE 2542,21 kWh/a
  • HVAC
  • rejected heat capacity* 290 W
    dehumidification* 0 Liter/24h
  • Refrigeration system
  • refrigerant type R-290 (HC) GWP 3
    refrigerant charge max. 0,130 kg
    max. allowable operating pressure 30 bar
  • General
  • minimum duration of the guarantee offered by the supplier

*… declared for climate class 3, test procedure according to EN 23953-2
**… with process-related interior fitting
“The manufacturer reserves the right to change the product specifications without notice”